Radiation Therapy Phantom (ART)

Proud to be MADE IN THE USA

The Alderson Radiation Therapy phantom (ART) and its earlier version, the Alderson RANDO phantom, have been in use for over 30 years. The ART has been refined and improved in both design and materials. These phantoms are indispensable quality-assurance tools; about 10,000 are in use all over the world. They provide integrated tests of the entire chain of treatment planning and delivery.

ART phantoms are molded of tissue-equivalent material; they are designed within highly sophisticated technological constraints and follow ICRU-44 standards. They are also designed for accuracy and ease of use. a large female.

ANATOMY
The male ART represents a 175 cm (5 ft. 9 in.) tall, 73.5 kg (162 lb.) male, and the female ART represents a 155 cm (5 ft. 1 in.) tall, 50 kg (110 lb.) female.

The ART phantom is transected-horizontally into 2.5 cm thick slices. Each slice has holes which are plugged with bone-equivalent, soft-tissue-equivalent or lung tissue equivalent pins which can be replaced by TLD holder pins. The holder pins are ordered separately.

Soft-tissue-equivalent coatings produce slices with glass smooth interfaces. These coatings are cut away over the air spaces of the oronasal pharynges, trachea and stem bronchi. Dosimetry holes are drilled in grids 3 cm x 3 cm or 1.5 cm x 1.5 cm in 5 and 7 mm diameters. These afford detailed measurements of dose distributions.

BREAST ATTACHMENTS
There is poor correlation between clothing brassiere sizes and breast volumes. Breasts are specified according to this table:

Volume
200 ml
400 ml
600 ml
900 ml
1200 ml
Approximate Clothing Size
A
B
C
D
DD


Breasts are available in various sizes. They can be sliced in frontal planes (drilled or undrilled for film dosimetry). Slices can receive any of the pins listed below. Breasts of male and female ART phantoms are contoured to blend realistically with the thoraxes. They are attached to the thorax with nylon screws. The male chest with breasts attached serves as a large female.

MATERIALS
Soft Tissues: There are unlimited, small variations in density and absorption throughout the human body. Phantom soft tissue is closely controlled to have the average density of these tissues.


Skeletons: RSD skeletons are highly-detailed polymer moldings which reproduce the shape, mass density and attenuation coefficients of cortical bone and spongiosa. They allow continuous production of phantoms, instead of the sporadic production required by the limited availability, variable size and uncertain chemical composition of human skeletons. These problems, plus loss of marrows in dried
natural skeletons, make RSD skeletons superior to “real bone”.

Molds for the RSD cortical bone and spongiosa were made from human skeletons consistent with the sizes of the softtissue molds.

RSD skeletons conform closely to the standards established by the International Commission on Radiation Units and Measurements (ICRU Report No. 44); mass density is reduced slightly to take into account a small decrease in calcium content for older patients.

Lungs: Lungs are molded from syntactic foam, with a specific gravity of 0.30 g/cc.

TLD DOSIMETERS AND FITTINGS
Phantoms are shipped with all dosimetry holes filled with blank pins. Pins for TLD chips have recesses at one end 3.2 x 3.2 x 0.9 mm. Pins for TLD rods have 1 mm-diameter holes cross-drilled at the centers of the pins. All pins are 2.50 cm long unless otherwise specified.

TLD DOSIMETERS AND HOLDERS

  Catalog No.
TLD Chip Holders – 5 mm or 7 m ART-10
TLD Rod Holders
1 mm diameter x 3 mm long – 5 mm or 7 mm
ART-12
TLD Rod Holders
1 mm diameter x 6 mm long – 7 mm only
ART-15
Blank Pins – 5 mm diameter ART-20-S, L, B
Blank Pins – 7 mm diameter ART-21-S, L, B
S = Soft Tissue Equivalent
L = Lung Tissue Equivalent
B = Bone Tissue Equivalent
 
Note: ART-10 and ART-12 are interchangeable in ART phantoms.  

ASSEMBLY

ART phantom slices are held between aluminum plates by nylon tie rods. Knobs at the end of the rods clamp the slices tightly in proper alignment.
 


Both internal and external assembly devices are included. The external assembly facilitates film dosimetry, while the internal assembly is used generally with TLDs or ion chamber dosimetry.
 

  UNDRILLED 3 CM X 3 CM

GRID HOLE SPACING

15 CM X 1.5 CM

GRID HOLD SPACING

Male ART Phantom          (Sections 0-35) ART-200X ART-200 ART-200A
Male ART Head and Neck Phantom (Sections 0-9) ART-210X ART-210 ART-210A
Male ART Chest Phantom (Sections 10-25) ART-211X ART-211 ART-211A
Male ART Pelvis Phantom (Sections 26-35) ART-212X ART-212 ART-212A
Female ART Phantom   (Sections 0-32) ART-300X ART-300 ART-300A
Female ART  Head and Neck  Phantom (Sections 0-9) ART-310X ART-310 ART-310A
Female ART Chest Phantom (Sections 10-23) ART-311X ART-311 ART-311A
Female ART Pelvis Phantom (Sections 24-32) ART-312X ART-312 ART-312A

 

 Breast Attachments      
Male Breasts ART-250-A-B-C-D-E   Example:
Female Breasts ART-350-A-B-C-D-E   ART-250-4-S-3.0-7-P  =
Volume: 200, 400, 600, 900, 1200 ml A = 2, 4, 6, 9, or 12   Male Breast - 400 ml-
Sliced or Unsliced B = S or U   sliced - 3 x 3 grid - 7 mm
Hold Grid C = 1.5, 3.0 or 0   diameter-pair
1.5 x 1.5  or  3.0 x 3.0 cm or none      
Hole Size D = 5 or 7    
5 or 7 mm diameters or N/A      
Side - Left, Right or pair E = L, R or P    

We also offer our Whole Body Pixy, Wounded Willy and Damaged Debbie along with sectional phantoms for all your modalities.

 