| All functions microprocessor controlled
|
| Ultra-fast response time |
| Automatic range selection ranges up to
9.999 curies of F-18 |
| Pre-programmed for 511 keV radionuclides
|
| Display in Curies or Becquerels
|
| Automatic background subtraction and
zeroing at the touch of a button |
| Remote ionization chamber with .25" (.64
cm) lead shielding and 10-foot cable |
| Self-diagnostic software |
| Daily constancy isotope keys |
| Electronic power supply (no battery in
chamber) |
| RS-232 bi-directional serial
communications port |
| Industry exclusive two-year warranty
|
| ETL to UL 3101-1 and cETL to CAN/CSA C22.2
No. 1010.1-M92 |
The Atomlab 300 Dose Calibrator's
ultra-fast response time, extended measurement range and computer
compatibility provide state-of-the-art performance for PET pharmacies,
chemistry laboratories or clinics. The Atomlab 300 provides fast, accurate
radionuclide activity measurements that easily surpass the most stringent
regulatory requirements. With a modular design, the Atomlab 300 can be
configured to specific requirements and expanded as the facility grows.
The unit is simple to operate. There are 13
isotope selection keys, ten are pre-programmed for the most commonly used
PET and constancy radionuclides and three are user defined. Any key can be
reprogrammed by the user for a desired isotope.
Activity is displayed on a LED readout
in either Curie or Becquerel units. Background correction and zero
adjustment are performed at the touch of a button. Range selection is
automatic.
Activity measurements are performed by a
microprocessor controlled electrometer located within the detector assembly
of the ionization chamber. The chamber is shielded with .25" (.64 cm) lead.
Up to six remote chambers and a printer may be connected to a single display
unit. Utilizing the Multi-Chamber Switch Box, the chambers may be placed as
far as 40 feet away from the display unit. Chamber bias is generated within
the display unit by an electronic high voltage supply, eliminating the need
for expensive battery changes.
The RS-232 port enables the Atomlab 300 Dose
Calibrator to communicate with most commercially available nuclear medicine
management systems.
An industry exclusive two-year warranty is
standard.
| Measurement Range: 0.01 µCi to 9999 mCi,
auto-ranging |
| Display Ranges (Units are
user-selectable):
Ci |
Bq |
0.01-19.99 µCi |
.001-1.999 MBq (=54 µCi) |
20.0-199.0 µCi |
2.00-19.99 MBq (=540 µCi) |
200-1999 µCi |
20.0-1999.0 MBq (=5.5 mCi) |
2.00-19.99 mCi |
.200-1.999 GBq (=54 mCi) |
20.0-199.0 mCi |
2.00-19.909 GBq (=54 mCi) |
200-9999 mCi |
20.0-399.9 GBq (=10.8 Ci) |
|
| Isotope Selection Keys:
Ten factory programmed — C-11; N-13; O-15; F-18; Cu-62; Ga-68; Rb-82;
I-124; Co-57; Cs-137
Three additional keys for user-defined isotopes |
| Activity Range: 0.01 µCi to 9999 mCi (.001
MBq to 399.9 GBq) |
| Energy Range: 25 keV to 3 MeV photons
|
| Response Time (Auto Selection): One second
above 20 µCi; Three seconds between 2 µCi and 20 µCi; 10 seconds below 2
µCi |
| Detector Linearity: ±1% or 0.2 µCi,
whichever is greater |
| Electrometer Linearity: ±1% or 0.2 µCi,
whichever is greater |
| Electrometer Accuracy: ±1% or 0.2 µCi,
whichever is greater |
| Overall Accuracy: ±4% or 0.4 µCi,
whichever is greater. Overall accuracy is affected by such factors as the
accuracy of the specific source calibration, geometric variations due to
sample volume or configuration, detector linearity, electrometer accuracy
and readout accuracy |
| Repeatability: ±0.3% above 1 mCi short
term (24 hr); 1% long term (1 yr); exclusive of background |
| Digital Calibration Dial: Four-digit LED
dial display with increment/decrement keys to change the value. Range is
from 0.1 to 999 |
| Detector: Well-type pressurized ionization
chamber, with Argon fill gas; Well opening 2.75" (7 cm), well depth is
10.5" (26.7 cm) |
| Detector Shielding:.25" (6.3 mm) lead on
all sides except top well opening. Supplementary shielding available.
|
| Chamber Bias: 340 volt electronic power
supply |
| Environmental Operating Conditions:
Temperature: 0-40° C; Humidity: 0-90% rh, non-condensing |
| Power Requirements: 100 to 120 VAC @ 1/2A;
200 to 240 VAC @ 1/4A |
| Line Frequency: 50/60 Hz; Detachable line
cord; Built-in EMI filter and transient suppression |
| Detector and Interface Cables: 30' (914.4
cm) long, six conductor cables (two carry power, one is chassis ground,
three carry serial data for digital I/O) Ends terminated with AMP
Mate-n-Lock connectors, white with hooded strain relief |
| Display Unit:
Dimensions: 12" w x 14.3" d x 3.75" h
(30.5 x 36.3 x 9.5 cm)
Weight: 6 lb (3 kg) |
| Detector Unit:
Dimensions: 7.5" w x 7.5" d x 16.25" h (19 x 19 x 41.3 cm)
Well Internal Dimensions: 2.75" dia x 10.5" h (7 x 26.7 cm)
Well Internal Dimensions with Liner:
2.5" dia x 10.25" h (6.35 x 26 cm)
Overall Weight: 35 lb (16 kg)
Well Shielding: .25" lead (.63 cm) |
| Approvals:
ETL to UL 3101-1 and ©ETL to CAN/CSA C22.2 No. 1010.1-M92 |